Parameterization

This page shows how to parameterize the Xtract DeltaQ component using SSIS variables directly in the component and by using SSIS expressions to set Data Flow Properties.

Parameterization using SSIS Variables

SSIS variables store values that an SQL Server Integration Services package and its containers, tasks, and event handlers can use at runtime.

You can use SSIS variables for selections. Available SSIS variables are listed in the selection settings when parameter input ( ) is selected, see Edit Selections.

Use SSIS Variables with @-Notation

The following input fields in the Xtract DeltaQ component allow entry of an SSIS variable:

To use SSIS variables in input fields of the component, place an @ symbol before the variable name.

  1. Choose an input field that supports SSIS variables.
  2. Instead of entering a fixed a value, enter a variable name using the @-notation, e.g., @vDate.
  3. Create a new SSIS variable with the same name, but without the @ symbol, e.g., vDate.
  4. Make sure to select the correct data type.

You can now use the SSIS variable to set dynamic input values for the input field.

Parameterization using Expression Properties

The recommended way of parameterization is to use SSIS expressions to set Data Flow Properties. Data Flow Properties are displayed in the "Properties" window of the Data Flow Task.

Note

Data Flow Properties are not to be confused with Custom Properties that are displayed in the "Properties" window of the component. When parameterizing the Data Flow Properties, the Custom Properties are overwritten.

For more information on property expressions, see Microsoft Documentation: Use Property Expressions in Packages.

  1. Right-click the Data Flow canvas and select Properties. The window "Properties" opens.
  2. Add an Expression by clicking using […]. The window "Property Expression Editor" opens.
    Expressions
  3. Select a property from the drop-down list under Property.
  4. Open the "Expression Builder" using the […] button under Expression.
  5. Build your Expression and click [Evaluate Expression] to check for correct syntax.
  6. Confirm your input with [OK].

Data Flow Properties of Xtract DeltaQ

List of Data Flow Properties that can be parameterized:

Property Description
[Xtract DeltaQ].[GatewayHost] Corresponds to the setting Gateway Host in the Xtract DeltaQ component.
[Xtract DeltaQ].[GatewayService] Corresponds to the setting Gateway Service in the Xtract DeltaQ component.
[Xtract DeltaQ].[ProgramID] Corresponds to the setting Program ID in the Xtract DeltaQ component.
[Xtract DeltaQ].[RequestID] Corresponds to the setting RequestID in the Xtract DeltaQ component.
[Xtract DeltaQ].[TargetSystem] Corresponds to the setting Logical Destination in the Xtract DeltaQ component.
[Xtract DeltaQ].[UpdateType] Corresponds to the drop-down menu Update Mode in the Xtract DeltaQ component. Permitted values are: Full (70), Delta (68), Init (67), InitNoData (83), Repeat (82), InitNonCumulative (73), Activate (65).

Custom Properties of Xtract DeltaQ

The Custom Properties are properties that are unique to the component. When parameterizing the component using SSIS variables, the Custom Properties are overwritten.

The Custom Properties of the Xtract DeltaQ component are displayed in the "Properties" window.

deltaq-properties

List of the relevant Custom Properties:

Property Description
GatewayHost Corresponds to the setting Gateway Host in the Xtract DeltaQ component.
GatewayService Corresponds to the setting Gateway Service in the Xtract DeltaQ component.
HierClass Corresponds to the setting Hierarchy Class in the Xtract DeltaQ component.
HierName Corresponds to the setting Hierarchy Name in the Xtract DeltaQ component.
Language Corresponds to the setting Language in the Xtract DeltaQ component.
NewTimeStampFormatInRequestLog If this value is set to true (X), the format of the timestamp in the request log is changed.
OLTPSourceName Name of the OLTP source to be extracted.
OLTPSourceType Type of the OLTP source to be extracted.
ProgramID Corresponds to the setting Program ID in the Xtract DeltaQ component.
RequestID Corresponds to the setting RequestID in the Xtract DeltaQ component.
TargetSystem Corresponds to the setting Logical Destination in the Xtract DeltaQ component.
Timeout Sets a timeout for the extraction.
TransferMethod Corresponds to the setting Transfer Mode in the Xtract DeltaQ component (tRTF or IDoc).
TransferStructure The transfer structure of the source, e.g., ROHIEROS.
UpdateType Corresponds to the drop-down menu Update Mode in the Xtract DeltaQ component. Permitted values are: Full (70), Delta (68), Init (67), InitNoData (83), Repeat (82), InitNonCumulative (73), Activate (65).
UseLegacyVarUpdate Set to True for backward compatibility with extractions that use the deprecated update mode (V)Variable.
UseWideString Defines whether DT_WSTR / DT_NTEXT (true) or DT_STR / DT_TEXT (false) is used as the data type for string columns.